Reference Guide

Applicable Systems All PowerEdge systems.
--MemPatrolScrub
Valid Arguments
On systems prior to 12G: NA
On 12G and later systems: Standard, Extended, Disabled
Description
Sets the Memory Patrol Scrub frequency as Standard Mode,
Extended Mode, or Disabled.
Example:
A:>syscfg --MemPatrolScrub=Standard
MemPatrolScrub=Standard
Applicable Systems PowerEdge 12G and later systems.
--MemRefreshRate
Valid Arguments
On systems prior to 12G: NA
On 12G and later systems: 1x, 2x
Description
Sets the Memory Refresh Rate as 1x or 2x
Example:
A:>syscfg --MemRefreshRate=1x
MemRefreshRate=1x
Applicable Systems PowerEdge 12G and later systems.
--MemVolt
Valid Arguments
On systems prior to 12G: NA
On 12G and later systems: AutoVolt, Volt15V, Volt135V
NOTE: Volt15V represents 1.5 Volt and Volt135V represents
1.35 Volt.
Description
Sets the DIMM voltage selection.
Example:
A:>syscfg --MemVolt=AutoVolt
MemVolt=AutoVolt
Applicable Systems PowerEdge 12G and later systems.
--MonitorMwait
Valid Arguments
On systems prior to 12G: NA
94