Reference Guide
--IntegratedRaid/--integratedraid
Valid Arguments
• On systems prior to 12G: enable, disable
• On 12G and later systems: Enabled, Disabled
Description
Enables or disables the integrated RAID controller. This option can be
replicated.
Example:
A:>syscfg --integratedraid=disable
integratedraid=disable
Applicable Systems All PowerEdge systems.
--IntegratedSas/--integratedsas
Valid Arguments
• On systems prior to 12G: enable, disable
• On 12G and later systems: Enabled, Disabled
Description
Enables or disables the integrated SAS controller. This option can be
replicated.
Example:
A:>syscfg --integratedsas=enable
integratedsas=enable
Applicable Systems All PowerEdge systems.
--InternalSdCard/--embsdcard
Valid Arguments
• On systems prior to 12G: on, off
• On 12G and later systems: On, Off
Description
Enables or disables the embedded SD card port.
Example:
A:>syscfg --embsdcard=off
embsdcard=off
Applicable Systems All PowerEdge systems
--InternalSdCardRedundancy/--embsdcardredundancy
Valid Arguments
• On systems prior to 12G: mirrormode, disable
50