Reference Guide
Mandatory
Options and
Arguments
Optional
Parameters
Valid Parameters
Arguments
Description
ch:targ,ch:tar
g, ... [or
ch:targ:encl,.
..]
or
controller
action=
createvdisk
controllerid=
id
adisk=
channel:target
: lun,
channel:target
: lun,...
[or
channel:target
:
enclosure,...]
disk space used on each array disk
included in the stripe. A valid argument
is a number that is less than the size of
the virtual disk. The -sszoption is
optional and can be added to the
command line in any order after the
mandatory option combination.
However, do not specify a unit for stripe
size when creating virtual disks. The unit
is always displayed in KB.
For SCSI controllers, the value of LUN
should always be 0.
For SAS controllers, the value of
enclosure can be non-zero, in which
case you must specify values for
channel, target, and enclosure.
-ctrl -ac=cvd -
c=id -ad=
ch:targ,ch:tar
g , ... [or
ch:targ:encl,.
..]
or
controller
action=
createvdisk
controllerid=
id
adisk=
channel:target
: lun,
channel:target
: lun,... [or
channel:target
: enclosure,..
-str or strict <number>
Strict (-str parameter) is the percentage
of expected array disk utilization.
Example:
A:> raidcfg -ctrl -ac=
cvd -c=0 -ad=0:0,0:1 -
r=1 -str=20
If the unused portion of an array disk is
greater than the mentioned percentage,
raidcfg aborts.
For SCSI controllers, the value of LUN
should always be 0.
For SAS controllers, the value of
enclosure can be non-zero, in which
case you must specify values for
channel, target, and enclosure.
-ctrl -ac=cvd
-c=id -ad=
ch:targ,ch:tar
g, ... [or
ch:targ:encl,.
..]
or
controller
action=
-sz or -size <number>
Sets the maximum size of the virtual disk
in MB or GB. A valid argument is a
number representing the maximum size
for the virtual disk. The -szoption is
optional and can be the added to the
command line in any order after the
mandatory option combination.
The minimum virtual disk size that you
can create for various controllers is as
follows:
• For PERC 5 controllers:
172