Reference Guide

Option Sub-option Valid Arguments Description
systempowerfa
il
--filteraction powercycle,
reset,
powerdown,
power
reduction,
none
Sets the event filter action for the filter
specified using the filter sub-
option. This sub-option depends on
the filter sub-option. This sub-
option can be replicated.
--hostname
<string>
Sets the host name (maximum of 62
printable ASCII characters) for the
BMC. This sub-option can be
replicated.
The hostname string must comprise
only the followig characters: hyphen
(-) , underscore (_) , and period (.) .
--filteralert
enable,
disable
Enables or disables alerts for the filter
specified using the filter sub-option.
This sub-option is dependent on the
filter sub-option. This sub-option can
be replicated.
--alertpolnum
1, 2, 3, 4
Specifies the alert policy entry
number. This sub-option can be
replicated.
--alertpolstatus enable,
disable
Enables or disables the alert policy
specified using the alertpolnum
sub-option. This sub-option can be
replicated. This sub-option is
dependent on the alertpolnum sub-
option.
Example: (to set the PEF configuration
parameters):
Example 1 (To configure the PEF so
that the system is powered down in
response to a fan failure event):
A:>syscfg pefcfgparams --
filter= fanfail--
filteraction=powerdown
pefcfgparams filter=fanfail
filteraction=powerdown
Example 2 (To configure the PEF so
that a PEF alert is not sent to the
138