chassistype*
Option Sub-option Valid Arguments Description
--chassistype*
NA NA
Identifies the Chassis Management
Controller (CMC). The possible values
are 9 (M1000e), 10 (VRTX), and 0
(others).
Example:
A:>syscfg -- chassistype
chassistype=10 (VRTX)
clearsel*
Option Sub-option Valid Arguments Description
--clearsel*
NA NA
Clears the System Event Log (SEL). This
option cannot be replicated.
Example:
A:>syscfg -- clearsel
Clearing SEL...
controlpanelaccess
Option Sub-option Valid Arguments Description
--controlpanelaccess
NA
viewandmodify
, viewonly,
disabled
Sets or gets the access level for the
Liquid Crystal Display (LCD).
Example:
A:>syscfg --
controlpanelaccess=
viewandmodify
controlpanelaccess=
viewandmodify
deviceguid*
Option Sub-option Valid Arguments Description
--deviceguid*
NA NA
Displays the GUID for the BMC. This
option cannot be replicated.
Example:
A:>syscfg--deviceguid
deviceguid=XXXXXXXXXX
119