Reference Guide
UEFI Boot Settings
You can manage the UEFI settings using the options in this group.
--UefiBootSeq
Valid Arguments
• On systems prior to 12G
: NA
• On 12G and later systems
: list of device names separated by commas
Description
Enables, disables, and orders the devices in a UEFI boot order list.
Only the devices present on the system are listed in the UefiBootSeq.
The first option in the list is attempted first. If the first option is not
successful, the second option is attempted, and so on. The system
attempts to launch only the enabled boot options and does not
launch disabled boot options. This option is applicable when
bootmodeis set to UEFIand has no effect when bootmode is set to
BIOS.
NOTE: Only the devices listed in the bootseq are enabled.
Applicable Systems All PowerEdge 12 and later systems.
SYSCFG Options On PowerEdge Systems Prior To PowerEdge 12G Systems
The following are the valid options and arguments supported on PowerEdge systems earlier than
PowerEdge 12G systems.
--assignintr
Valid Arguments
standard, distributed
Description Controls the interrupt assignment of PCI devices in the system. This
option is set to standard by default, causing standard interrupt
routing that uses interrupt A, B, C, and D for all PCIe devices. When
set to distributed, the interrupt routing is swizzled at the MCH root
ports to minimize sharing of interrupts across all PCIe (and PCI-X in
the Programmable Interrupt Controller (PIC) mode) devices.
Example:
A:>syscfg --assignintr=standard
assignintr=standard
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
--bezelir
Valid Arguments
enable, disable
Description Enables or disables the ESM to monitor and log front bezel intrusion
conditions.