Reference Guide
Example:
A:>syscfg --ExtSerialConnector=Serial1
--FailSafeBaud
Valid Arguments 115200, 57600, 19200, 9600
Description
Sets the console redirection fail safe baud rate in bps. The BIOS
attempts to determine the baud rate automatically. This failsafe baud
rate is used only if the attempt fails.
Example:
A:>syscfg --FailSafeBaud=9600
--RedirAfterBoot
Valid Arguments
Enabled, Disabled
Description
Sets the BIOS console redirection to enable or disable when the
operating system is loaded.
Example:
A:>syscfg --RedirAfterBoot=Enabled
--SerialComm
Valid Arguments
OnNoConRedir, OnConRedirCom1, OnConRedirCom2, Off
Description
Enables or disables the serial communication devices (Serial Device 1
and Serial Device 2) in BIOS.
Example:
A:>syscfg --SerialComm=OnNoConRedir
--SerialPortAddress
Valid Arguments
Serial1Com1Serial2Com2, Serial1Com2Serial2Com1, Com1, Com2
Description
Sets the port address of the serial devices. This option can be
replicated.
Example:
A:>syscfg --SerialPortAddress=Serial1Com1Serial2Com2
Slot Disablement
You can manage the slot disablement settings using the options in this group.
63