Reference Guide
Discarding Preserved Cache
The following table lists the RAIDCFG options, parameters, and pre-defined arguments for discarding the
preserved cache on the controller.
Table 41. Discarding Preserved Cache
Mandatory
Options and
Arguments
Optional
Parameters
Valid Parameters
Arguments
Description
--ctrl -c=id -
ac=dpc -force
or
controller
controllerid=i
d
action=discard
PreservedCache
—force
NA NA
Discards the preserved cache on the
controller.
Example:
A:>raidcfg -ctrl -c=2 -ac=dpc -
force
RAIDCFG Command successful!
--ctrl -c=id -
ac=dpc -force
-igncfg
or
controller
controllerid=i
d
action=discard
PreservedCache
—force -
ignoreconfig
NA NA
Discards the preserved cache on the
controller ignoring the foreign
configuration.
Example:
A:>raidcfg -ctrl -c=2 -ac=dpc -
force -igncfg
RAIDCFG Command successful!
RAID Replication Options
The following table lists the RAID replication options.
Table 42. RAID Replication Options
Mandatory
Options and
Arguments
Optional
Parameters
Valid Parameters
Arguments
Description
-i
NA <filename>
Reads the RAID configuration
information from the given .ini filename
and creates the RAID configurations on
the specified controllers. This option is
mandatory.
145