Reference Guide
Example:
A:>syscfg --embideraid=on
embideraid=on
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
--embnic1
Valid Arguments on, off, onnopxe, onwithiscsi
Description
Turns the first embedded NIC on with PXE on, off, or on without PXE
enabled. This option is only valid for supported systems that have a
NIC. If the NIC is enabled without PXE, it is not found in the boot
order. If the NIC is turned on with PXE, it is placed at the end of the
boot order. The onnopxe argument is not supported on all systems.
The onwithiscsi argument enables the embedded NIC to boot from
the iSCSI server. The embnic1 option can be replicated.
Example:
A:>syscfg --embnic1=onnopxe
embnic1=onnopxe
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
--embnic1nic2
Valid Arguments
enable, disable
Description
Enables or disables the operating system interface of the first and
second embedded NIC controllers.
Example:
A:>syscfg --embnic1nic2=enable
--embnic1nic2=enable
Applicable Systems PowerEdge 1855, PowerEdge 6850, and PowerEdge 11G systems
--embnic1pxe
Valid Arguments
enable, disable
Description
Enables or disables Preboot Execution Environment (PXE) on the first
embedded NIC. If PXE is disabled, the first NIC is not found in the
boot order. If PXE is enabled, the first NIC is placed at the end of the
boot order. This option is only present on systems that do not
support the embnic1 option. This option can be replicated.
Example:
A:>syscfg --embnic1pxe=enable
embnic1pxe=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
92