Reference Guide
solcfgparams
Table 49. solcfgparams options
Option Sub-option Valid
Arguments
Description Applicable Systems
solcfgpara
ms
Configures and displays SOL
configuration parameters. This
option can be replicated.
All PowerEdge
systems
--solenable enable,
disable
Enables or disables if the SOL
payload type can be activated.
This option can be replicated.
--solprivlevel user,
operator,
administra
tor
Sets the minimum user privilege
level required to activate the SOL.
This option can be replicated.
--
solcharaccuminte
rval
1–255
Sets the Character Accumulate
Interval in 5–ms increments (1–
255). This sets the typical amount
of time that the BMC waits before
transmitting a partial SOL
character data packet. This
option can be replicated.
--
solcharsendthres
hold
1–255
Specifies that the BMC
automatically sends an SOL
character data packet containing
this number of characters in
increments of 5 (1–255) as soon
as this number of characters (or
greater) has been accepted from
the baseboard serial controller
into the BMC. This option can be
replicated.
NOTE: On PowerEdge 9G
and SC1435 systems, the
maximum limit is 255.
--solbitrate
9600,
19200,
57600,
115200
Sets the serial channel
communication bit rate (in bps)
with the BMC when SOL is
activated. This option can be
replicated.
NOTE: The arguments for
solbitrate vary with
various Dell systems. If an
argument valid for a
particular Dell system is
entered for another system,
the Parameter out of
range
error is displayed.
Valid arguments are:
94