Reference Guide
Option Sub-option Valid
Arguments
Description Applicable Systems
Example 1 (To configure the PEF so
that the system is powered down
in response to a fan failure event):
A:>syscfg pefcfgparams
--filter= fanfail--
filteraction=powerdown
pefcfgparams
filter=fanfail
filteraction=powerdown
Example 2 (To configure the PEF so
that a PEF alert is not sent to the
destination IP address in response
to a chassis intrusion event):
A:>syscfg pefcfgparams
--filter= intrusion--
filteralert=disable
pefcfgparams filter=
intrusion
filteralert=disable
powerbutton
Table 42. powerbutton option
Option Sub-option Valid Arguments Description Applicable Systems
--
powerbutton
NA
enable,
disable
Enables or disables the power
button. This option can be
replicated.
Example:
A:>syscfg --
powerbutton=enable
powerbutton=enable
All PowerEdge
systems
powerctl
Table 43. powerctl option
Option Sub-option Valid Arguments Description Applicable Systems
--powerctl
NA
powerdown
</argument>
Performs a chassis powerdown and
controls the reset of the system.
Powerdown turns off the system.
All PowerEdge
systems
powercycle
</argument>
Turns off the system and
automatically turns on your system
after a few seconds.
reset </
argument>
Resets the system.
88