Reference Guide

Option Sub-option Valid Arguments Description Applicable Systems
DRAC 5
controller
--action setpassword
,
testpasswor
d
Sets or tests the password for the
specified User ID. This sub-option
cannot be replicated.
--password <string>
Sets the password (maximum of 16
printable ASCII characters) for the
specified BMC User ID. This sub-
option cannot be replicated.
Example (to set and test the
password for User ID 3):
A:>syscfg
passwordaction --
userid=3 --
action=setpassword --
password=bmcmaster
passwordaction userid=3
action=setpassword
password=*********
A:>syscfg
passwordaction --
userid=3 --
action=testpassword --
password=bmcmastor
Password test failed.
pefcfgparams
Table 41. pefcfgparams options
Option Sub-option Valid
Arguments
Description Applicable Systems
pefcfgparam
s or pcp
Configures and displays PEF
configuration parameters. This
option can be replicated.
All PowerEdge
systems
--filter fanfail,
voltfail,
discretevo
ltfail,
tempwarn,
tempfail,
intrusion,
redundegra
ded,redunl
ost,
procwarn,
procfail,
powerwarn,
powerfail,
hardwarelo
gfail,
autorecove
Specifies a PEF value. This sub-
option can be replicated.
For a complete list of all possible
PEF messages along a description
of each event, see BMC Platform
Events Filter Alert Messages
NOTE: The fanfail option
is not supported on
PowerEdge 10G systems.
86