Reference Guide
Option Sub-option Valid
Arguments
Description Applicable Systems
Example 1:
A:>syscfg --bootseq
Device 1: floppy.emb.0
- Diskette Drive A:
Device 2: cdrom.emb.0
- CD-ROM device
Device 3: hdd.emb.0 -
Hard Drive C:
Device 4: nic.emb.1 -
Intel Boot Agent
Version 4.0.17
Device 5: nic.emb.2 -
Intel Boot Agent
Version 4.0.17
Example 2:
A:>syscfg --
nextboot=nic.emb.1
nextboot=nic.emb.1
nmibutton
Table 39. nmibutton option
Option Sub-option Valid Arguments Description Applicable Systems
--nmibutton
NA
enable,
disable
Enables or disables the NMI button.
This option can be replicated.
Example:
A:>syscfg --
nmibutton=enable
nmibutton=enable
All PowerEdge
systems
passwordaction
Table 40. passwordaction options
Option Sub-option Valid Arguments Description Applicable Systems
passwordact
ion
Configures and tests the password
for the specified User ID. This option
cannot be replicated. All three sub-
options, action, userid, and
password must be included in the
command line.
NOTE: This option does not
support 20 byte passwords.
All PowerEdge
systems
--userid
2–16, if your
system has a
Specifies the BMC User ID. This
sub-option cannot be replicated.
85