Reference Guide

Example:
A:>syscfg --embnic1pxe=enable
embnic1pxe=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--embnic2pxe
Option
--embnic2pxe
Valid Arguments enable, disable
Description
Enables or disables Preboot Execution Environment (PXE) on the second
embedded NIC. If PXE is disabled, the second NIC is not found in the boot
order. If PXE is enabled, the second NIC is placed at the end of the boot order.
This option is only present on systems that do not support the embnic2 option.
This option can be replicated.
Example:
A:>syscfg --embnic2pxe=enable
embnic2pxe=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--embsataraid
Option
--embsataraid
Valid Arguments off, combined, ata, ahci, raid, qdma
Description
Configures an embedded SATA RAID controller. This option can be replicated.
off — disables the embedded SATA RAID controller.
combined — sets the SATA RAID controller to combined mode.
ata — sets SATA RAID controller to ATA mode.
ahci — sets ATA RAID controller to ahci mode.
raid — sets SATA RAID controller to RAID mode.
qdma — sets the SATA RAID controller to support ATAPI devices at
transfer rates much higher than PIO. A device driver must be installed on
your system to use the QDMA mode.
Example:
A:>syscfg --embsataraid=off
embsataraid=off
Applicable Systems
All PowerEdge systems prior to PowerEdge 12G systems.
--embscsi1
Option
--embscsi1
Valid Arguments
on, off
Description
Turns the first embedded SCSI controller. This option is only valid for supported
systems that have an embedded SCSI controller. This option can be replicated.
33