Reference Guide

--cmosdefaults
Option
--cmosdefaults
Valid Arguments enable, disable
Description
Enables or disables the request for a default CMOS value during the next
reboot.
A:>syscfg --cmosdefaults=enable
cmosdefaults=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--conboot
Option
--conboot
Valid Arguments enable, disable
Description
Enables or disables configuring or reporting of console redirection after reboot.
This option is available on all supported systems that support console
redirection. This option can be replicated.
Example:
A:>syscfg --conboot=enable
conboot=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12Gsystems.
--conred
Option
--conred
Valid Arguments serial1, serial2, off, bmcsol, mmb
Description
Configures or reports the communication port for console redirection. If this
option is set to serial port, then the serial port option is not available. If only one
serial port is present on a system, the serial2 argument is not available. This
option can be replicated.
Example:
A:>syscfg --conred=serial1
conred=serial1
Applicable Systems All PowerEdge systems prior to PowerEdge 9G systems.
--conterm
Option
--conterm
Valid Arguments vt100, ansi
Description
Configures or reports the terminal type for console redirection. This option is
available on all supported systems that support console redirection. This option
can be replicated.
26