Quick Reference Guide
Option Sub-option Valid Arguments Description Applicable Systems
--
majorfwvers
ion
NA Reports the BMC device major
firmware revision.
--
minorfwvers
ion
NA
Reports the BMC device minor
firmware revision.
Example:
A:>syscfg bmcversion
devid=32
devrevision=0
majorfwversion=0
minorfwversion=40
chassistype*
Table 25. chassistype option
Option Sub-option Valid Arguments Description Applicable Systems
--
chassistype
*
NA NA
Identifies the Chassis Management
Controller (CMC). The possible
values are 9 (M1000e), 10
(VRTX), and 0 (others).
Example:
A:>syscfg --
chassistype
chassistype=10 (VRTX)
All PowerEdge blade
systems
clearsel*
Table 26. clearsel option
Option Sub-option Valid Arguments Description Applicable Systems
--clearsel*
NA NA
Clears the System Event Log (SEL).
This option cannot be replicated.
Example:
A:>syscfg -- clearsel
Clearing SEL...
All PowerEdge
systems
controlpanelaccess
Table 27. controlpanelaccess options
Option Sub-option Valid
Arguments
Description Applicable Systems
--
controlpanelacce
ss
NA
viewandmod
ify,
Sets or gets the access level for
the Liquid Crystal Display (LCD).
PowerEdge 11G and
12G systems
78