Quick Reference Guide

Group Option Valid Arguments Description
30-second time-out if the last boot attempt
has failed.
Embedded Server Management
Table 11. Embedded Server Management Options
Group Option Valid Arguments Description
Embedded Server
Management
--FrontLcd None,
UserDefined,
ModelNum,
Advanced
Allows you to set the model number or a
user-defined string on the front-panel LCD
display.
--UserLcdStr <string>
Allows you to set the default string (model
name and number for PowerEdge systems
earlier than Dell PowerEdge 11G and
service tag for PowerEdge systems 11G
and later) or a user-defined string on the
front-panel LCD. The maximum length of
the string is 62 characters.
Integrated Devices
Table 12. Integrated Devices Options
Group Option Valid Arguments Description
Integrated
Devices
--EmbNicPortnBootProto Unknown, None,
Pxe, Iscsi
Controls the legacy boot protocol of the
LOM port specified by the embedded
NIC port number. This is a write-only
attribute. This attribute is for systems
management software use, and does
not appear in system BIOS setup. This
attribute always returns Unknown,
when read. There is no change to the
LOM port legacy boot protocol setting
when Unknown is returned. An error is
returned if written with a setting
(
None, PXE, or iSCSI) that is
not supported by the LOM Port.
--EmbVideo Enabled,
Disabled
Enables or disables the BIOS support
for the Embedded Video Controller.
--IntegratedNetwork1 Enabled,
DisabledOs,
Enables or disables Integrated Network
1.
NOTE: If set to DisabledOs, the
Integrated NICs may still be
available for shared network
access by the embedded
management controller. This
function must be configured
through the NIC management
utilities provided with your system.
--IntegratedNetwork2
Enabled,
DisabledOs
Enables or disables Integrated Network
2.