Quick Reference Guide

Description
Enables or disables vflash on iDRAC.
Example:
A:>syscfg --vflash=enable
vflash=enable
Applicable Systems All PowerEdge 11G systems or systems with iDRAC6
Sub Options And Arguments For tpm Option
The following table lists the sub-options and arguments for the tpm option.
Table 6. Sub-options and Arguments for the tpm Option
Option Sub-option Arguments Description
tpm --tpmsecurity
off Does not report the presence of TPM to the
operating system.
onwithpbm Directs the BIOS to store the TCG compliant
measurements to the TPM during a POST
operation.
onwithoutpbm Directs the BIOS to bypass the preboot
measurements.
Example:
A:>syscfg tpm --
tpmsecurity=onwithoutpbm
--setuppwdoverride
--
tpmactivation
enabled Enables and activates the TPM feature.
disabled Disables and deactivates the TPM feature.
nochange Does not alter the operational state of the TPM
feature.
Example:
A:>syscfg tpm --
tpmactivation=enabled --
setuppwdoverride
NOTE: You cannot set tpmactivation when
tpmsecurity is set to off.
NOTE: After setting tpmactivation to enabled or
disabled, if you reboot your system, DTK
displays the TPM Configuration
Honoured system will reset and
the system reboots again
message
and reboots.
NOTE: When you set tpmactivation to enabled
or disabled, DTK displays the value of
tpmactivation as nochange. However, the TPM
feature is activated/deactivated when you
reboot the system.
59