Quick Reference Guide
--memprefailurenotify
Option
--memprefailurenotify
Valid Arguments enable, disable
Description
Enables or disables the Correctable ECC SMIs. When enabled, the SMIs report
the Correctable ECC errors.
This option can be replicated.
Example:
A:>syscfg --memprefailurenotify=enable
memprefailurenotify=enable
Applicable Systems PowerEdge R710, R610, and T610 systems with Intel Xeon processor
--memremap
Option
--memremap
Valid Arguments off, auto
Description
Sets the memory remapping to off or auto.
Example:
A:>syscfg --memremap=off
memremap=off
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--memtest
Option
--memtest
Valid Arguments enable, disable
Description
Enables or disables the POST extended memory test.
Example:
A:>syscfg --memtest=disable
memtest=disable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--mouse
Option
--mouse
Valid Arguments on, off
Description
Turns the mouse controller on or off.
This option can be replicated.
Example:
A:>syscfg --mouse=off
mouse=off
45