Quick Reference Guide
--f1f2promptonerror
Option
––f1f2 prompt onerror
Valid Arguments enable, disable
Description
Enables or disables the BIOS to prompt F1 or F2 error codes.
Example:
A:>syscfg --f1f2promptonerror=enable
f1f2promptonerror=enable
Applicable Systems PowerEdge 10G and later systems
--floppy
Option
--floppy
Valid Arguments auto, off, readonly
Description
Sets the diskette drive controller to auto, off, or readonly. This option is
available on all supported systems that have a supported diskette drive. This
option can be replicated
Example:
A:>syscfg --floppy=auto
floppy=auto
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--formfactor
Option
––formfactor
Valid Arguments read-only
Description
Displays the geometry of PowerEdge Blade systems. The option can have the
following values: halfheight (the Blade systems occupies 1 slot of the chassis),
halfheight, dualwide (the Blade system occupies 2 horizontal slots of the
chassis), fullheight (the Blade system occupies 2 vertical slots of the chassis),
fullheight, dualwide (the Blade system occupies 4 slots of the chassis).
NOTE: On 12G systems, the option will have an additional value,
quarterheight (the Blade systems occupies half slot of the chassis).
Example:
A:>syscfg --formfactor=fullheight, dualwide
formfactor=fullheight, dualwide
Applicable Systems All PowerEdge blade systems including 12G systems.
--fsbr
Option
--fsbr
Valid Arguments 115200, 57600, 19200, 9600
Description
Sets the console redirection fail safe baud rate in bps.
39