Quick Reference Guide

Mandatory Options
and Arguments
Optional Parameters Valid Parameters
Arguments
Description
Drive Vendor: FUJITSU
Drive Model: MAP3367NC
Drive Location: 0:2:0
Drive Size: 34680 MB
Drive Avail: 34680 MB
RAIDCFG Command successful!
-ad -ad=
ch:targ,ch:tar
g ,... -ac=
unblink -c=id
or adisk adisk=
channel:target
,
channel:target
,... -ac=
unblink
controllerid=
id vdisk=id
NA NA
Unblinks the specified physical disks on the
specified controller.
Example:
A:>raidcfg -ad -ad=0:1,0:2
ac=unblink -c=2
Controller: PERC 6/E
****** Physical Drive ******
Drive Vendor: SEAGATE
Drive Model: ST336607LC
Drive Location: 0:1:0
Drive Size: 34680 MB
Drive Avail: 0 MB
****** Physical Drive ******
Drive Vendor: FUJITSU
Drive Model: MAP3367NC
Drive Location: 0:2:0
Drive Size: 34680 MB
Drive Avail: 34680 MB
RAIDCFG Command successful!
Enumerating Virtual Disks
The following table lists the RAIDCFG options, parameters, and pre-defined arguments for enumerating virtual disks.
Table 64. Enumerating Virtual Disks
Mandatory Options
and Arguments
Optional Parameters Valid Parameters
Arguments
Description
—vd or vdisk
NA NA
Lists all the virtual disks for each controller
along with the array disks that make up each
virtual disk. This option is mandatory.
Example:
A:>raidcfg -vd
Controller: PERC 6/E
Virtual disk not found
Controller: PERC 6/E
VDisk ID: 0
Size: 34680 MB
Type: RAID 1
Read Policy: Normal Read Ahead
Write Policy: Writeback
Cache Policy: Direct_IO
Drives: 0:0:0,0:1:0
Controller: PERC 6/E
Virtual disk not found
126