Quick Reference Guide
Enumerating Array Disks
The following table lists the RAIDCFG options, parameters, and pre-defined arguments for enumerating array disks (hard
drives).
NOTE: You can also use pdisk or -pd instead of adisk or -ad to specify an array disk.
Table 62. Enumerating Array Disks (Hard Drives)
Mandatory Options
and Arguments
Optional Parameters Valid Parameters
Arguments
Description
-ad -c=id or
adisk
controllerid=i
d
NA NA
Lists all the array disks attached to the
specified RAID controller. This option
combination is mandatory.
NOTE: The following example displays
output of a Series 7 controller.
NOTE: Software controller does not
display the NegSpeed, CapSpeed,
Certified and Supported
parameters.
Example:
A:>raidcfg -ad -c=2
Controller: PERC H700 Adapter
****** Physical Drive ******
Vendor: DELL(tm)
Model: ST9146703SS
Protocol: SAS
Media: HDD
NegSpeed: 6144 Mbps
CapSpeed: 6144 Mbps
Certified: YES
Supported: YES
Location: 0:0:1
Size: 139392 MB (136 GB)
Avail: 0 MB
****** Physical Drive ******
Vendor: DELL(tm)
Model: ST9146703SS
Protocol: SAS
Media: HDD
NegSpeed: 6144 Mbps
CapSpeed: 6144 Mbps
Certified: YES
Supported: YES
Location: 0:1:1
Size: 139392 MB (136 GB)
Avail: 0 MB
****** Physical Drive ******
Vendor: DELL(tm)
123