User's Manual
When dealing with SAS devices, the array disk location is displayed as channel:target:enclosure. It is possible to have
the enclosure value as non-zero. If the enclosure has a non-zero value, then all three numbers (channel, target, and
enclosure) have to be included on the command line.
Q: Do I need to specify RAID type and size when creating virtual disk(s)?
A: No. The default RAID type is RAID 0. If RAID size is not provided, the maximum size allowed for virtual disk is created.
The mandatory fields required to create virtual disks are the controller slot ID and the array disks.
Q: What is a hotspare (failover drive)?
A: A hotspare is an extra and unused disk drive that is part of an array disk subsystem. A hotspare is always in standby
mode. If a disk failure occurs, the hotspare replaces the failed drive without interrupting the system.
Q: What is mr2kserv.exe?
A: This is a service needed to configure all LSI RAID controllers in Windows PE. It provides Plug and Play support.
Q: What features have changed from the MS-DOS version of RAIDCFG to the Windows PE and embedded Linux
versions?
A: Windows PE and embedded Linux version of RAIDCFG support new controllers. For the list of supported controllers,
see
Dell Systems Software Support Matrix
at dell.com/support/manuals.
Features that have been removed from the MS-DOS version include:
• The --name and --wait options in the create command
• The --runlocation and the --scratchlocation options
• The --getpercentcomplete environment variables
Q: What is the minimum virtual disk size that I can create?
A: For PERC 5 controllers:
• RAID 0: 100 MB
• RAID 1: 100 MB
• RAID 5: 100 MB
For PERC 6 controllers:
• RAID 0: 100 MB
• RAID 1: 100 MB
• RAID 5: 100 MB
• RAID 6: 100 MB
• RAID 60: 100 MB
Q: Why can I not see any controllers using RAIDCFG?
A: Ensure that the RAID controller(s) can be seen in the BIOS during POST. If the BIOS does not detect the controller,
then RAIDCFG does not detect it. Also ensure that the controller is set to RAID mode and not any other mode in the
controller BIOS.
Q: What is span length?
A: Span length is the field needed when you try to create a RAID 50. The number represents the span size of the RAID 5.
Q: PARTCFG cannot enumerate the virtual disk(s) created by RAIDCFG. What must be done?
A: A reboot is required for PARTCFG to enumerate virtual disks after creating a virtual disk using the RAIDCFG command.
SYSCFG Questions
Q: Can I use the SYSCFG utility to configure Point-to-Point Protocol (PPP) over the serial port to access my RAC?
67