Quick Reference Guide

Option Sub-option Valid
Arguments
Description Applicable Systems
less for PowerEdge 9G systems
and later.
--filteralert enable,
disable
Enables or disables alerts for the
filter specified using the filter sub-
option. This sub-option is
dependent on the filter sub-option.
This sub-option can be replicated.
--alertpolnum
1, 2, 3, 4
Specifies the alert policy entry
number. This sub-option can be
replicated.
--
alertpolstatu
s
enable,
disable
Enables or disables the alert policy
specified using the
alertpolnum sub-option. This
sub-option can be replicated. This
sub-option is dependent on the
alertpolnum sub-option.
Example: (to set the PEF
configuration parameters):
Example 1 (To configure the PEF so
that the system is powered down
in response to a fan failure event):
A:>syscfg pefcfgparams
--filter= fanfail--
filteraction=powerdown
pefcfgparams
filter=fanfail
filteraction=powerdown
Example 2 (To configure the PEF so
that a PEF alert is not sent to the
destination IP address in response
to a chassis intrusion event):
A:>syscfg pefcfgparams
--filter= intrusion--
filteralert=disable
pefcfgparams filter=
intrusion
filteralert=disable
powerbutton
Table 39. powerbutton option
Option Sub-option Valid Arguments Description Applicable Systems
--
powerbutton
NA
enable,
disable
Enables or disables the power
button. This option can be
replicated.
All PowerEdge
systems
90