Quick Reference Guide
Example:
A:>syscfg --memintleave=enable
memintleave=enable
NOTE: The memintleave option is same as Nodeinterleave option. For more
information, see
Memory Settings group.
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--memoperatingmode
Option
--memoperatingmode
Valid Arguments optimizer, mirror, advancedecc
Description
Selects the memory operating mode. This feature is active only if a valid
memory configuration is detected.
Example:
A:>syscfg --memoperatingmode=optimizer
memoperatingmode=optimizer
Applicable Systems PowerEdge 11G systems
--memprefailurenotify
Option
--memprefailurenotify
Valid Arguments enable, disable
Description
Enables or disables the Correctable ECC SMIs. When enabled, the SMIs report
the Correctable ECC errors.
This option can be replicated.
Example:
A:>syscfg --memprefailurenotify=enable
memprefailurenotify=enable
Applicable Systems PowerEdge R710, R610, and T610 systems with Intel Xeon processor
--memremap
Option
--memremap
Valid Arguments off, auto
Description
Sets the memory remapping to off or auto.
Example:
A:>syscfg --memremap=off
memremap=off
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
45