Quick Reference Guide
--adjcacheprefetch
Option
--adjcacheprefetch
Valid Arguments enable, disable
Description
When this option is set to enable, the processor fetches the cache line
containing the currently requested data, and the adjacent cache line. When
this option is set to disable, the processor fetches only the cache line
containing the currently requested data.
Example:
A:>syscfg --adjcacheprefetch=enable
adjcacheprefetch=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
--asset
Option
--asset
Valid Arguments <
string
>
Description Reports or sets the customer-programmable asset tag number for a system.
The maximum length of an asset tag is 10 characters. Asset tag values cannot
contain any spaces. For more information on delimiters, see Command Line
Option Delimiters. This value can be replicated.
Example:
A:>syscfg --asset=<ASSETTAG>
asset=ASSETTAG
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems except Blade
systems.
--assignintr
Option
--assignintr
Valid Arguments standard, distributed
Description Controls the interrupt assignment of PCI devices in the system. This option is
set to standardby default, causing standard interrupt routing that uses interrupt
A, B, C, and D for all PCIe devices. When set to distributed, the interrupt routing
is swizzled at the MCH root ports to minimize sharing of interrupts across all
PCIe (and PCI-X in the Programmable Interrupt Controller (PIC) mode) devices.
Example:
A:>syscfg --assignintr=standard
assignintr=standard
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
25