Quick Reference Guide

Blinking And Unblinking Array Disks
The following table lists the RAIDCFG options, parameters, and pre-defined arguments for blinking and unblinking array
disks (hard drives).
NOTE: You can also use pdisk or -pd instead of adisk or -ad to specify an array disk.
Table 60. Blinking And Unblinking Array Disks
Mandatory Options
and Arguments
Optional Parameters Valid Parameters
Arguments
Description
-ad -ad=
ch:targ,ch:tar
g ,... -
ac=blink -
c=id or adisk
adisk=
channel:target
,
channel:target
,... -ac=blink
controllerid=
id vdisk=id
NA NA
Blinks the specified physical disks on the
specified controller.
Example:
A:>raidcfg -ad -ad=0:1,0:2
ac=blink -c=2
Controller: PERC 6/E
****** Physical Drive ******
Drive Vendor: SEAGATE
Drive Model: ST336607LC
Drive Location: 0:1:0
Drive Size: 34680 MB
Drive Avail: 0 MB
****** Physical Drive ******
Drive Vendor: FUJITSU
Drive Model: MAP3367NC
Drive Location: 0:2:0
Drive Size: 34680 MB
Drive Avail: 34680 MB
RAIDCFG Command successful!
-ad -ad=
ch:targ,ch:tar
g ,... -ac=
unblink -c=id
or adisk adisk=
channel:target
,
channel:target
,... -ac=
unblink
controllerid=
id vdisk=id
NA NA
Unblinks the specified physical disks on the
specified controller.
Example:
A:>raidcfg -ad -ad=0:1,0:2
ac=unblink -c=2
Controller: PERC 6/E
****** Physical Drive ******
Drive Vendor: SEAGATE
Drive Model: ST336607LC
Drive Location: 0:1:0
Drive Size: 34680 MB
Drive Avail: 0 MB
****** Physical Drive ******
Drive Vendor: FUJITSU
Drive Model: MAP3367NC
Drive Location: 0:2:0
Drive Size: 34680 MB
Drive Avail: 34680 MB
RAIDCFG Command successful!
Enumerating Virtual Disks
The following table lists the RAIDCFG options, parameters, and pre-defined arguments for enumerating virtual disks.
126