Quick Reference Guide
206 RAIDCFG
Table 4-13. Function Calls of the setenvironment Option
Function Call Description
getfirmware Returns the firmware version of the specified controllers.
Example:
A:>raidcfg -se -envn=FIRMWARE -envc=
getfirmware -c=2
FIRMWARE=531T
RAIDCFG Command successful!
getcontrollertype Returns
LSI for LSI controllers and ADAP for Adaptec
controllers.
Example:
A:>raidcfg -se -envn=CONTROLLERTYPE -envc=
getcontrollertype -c=2
CONTROLLERTYPE=LSI
RAIDCFG Command successful!
getadisks Returns the array disks attached to the controller.
Example:
A:>raidcfg -se -envn=ADISKS -envc=getadisks -
c=2
ADISKS=0:0:1,0:1:1,0:2:1
RAIDCFG Command successful!
getfreeadiskcount Returns the number of free array disks found in the specified
controller.
Example:
A:>raidcfg -se -envn=FREEADISKCOUNT -envc=
getfreeadiskcount -c=2
FREEADISKCOUNT=2
RAIDCFG Command successful!