Owner's Manual
The "--devseq" option is present only if you have an available, bootable hard-disk partition. If this option is present
in the configuration file, but not present on your system, you will receive a usage error.
You may need to reboot your system for certain options to be enabled. Dell recommends you use the "reboot"
command on shell prompt or press the "Ctrl+Alt+Del" keys.
It is required to perform a warm reboot after applying the syscfg settings changes on Dell PowerEdge yx2x systems.
If you perform operations that change the "--redmem" option, reboot your system immediately. This is applicable
to both command-line and "--infile" usage.
NOTE: Additionally, the "--redmem" option should not be issued with any other command and should be
immediately followed by a system reboot. This is important when you develop scripts that can alter the "--
redmem" setting.
For options that use text strings such as username, password, hostname, and community string, using characters
such as <space>, "<," ">," "|," "=" on the command line can be misinterpreted by the command line parser and may
cause errors. To avoid such errors, use only alphanumeric characters.
If you set the username using syscfg username option, Serial Over Lan (SOL) access for the corresponding user will
be enabled by default. You can disable SOL access for a user using "syscfg solaction --userid=<userid> --
action=disable" command.
The maximum reliably supported baud rates (--solbitrate) are:
o
57600 for PowerEdge x9xx systems without Dell Remote Access Controller 5 (DRAC 5).
o
115200 for PowerEdge x9xx systems with DRAC 5.
If you enter an unsupported baud rate, you may receive an error, "Parameter out of range."
RAIDCFG
When creating virtual disks, the chunk (stripe) size is always in KBs. Do not specify any units of measure for the
chunk size.
When providing multiple physical disks for the "create virtual disk" command, do not separate the disks with spaces.
For example, "-ad=1:4, 1:5" causes an error. The correct way to input multiple physical disks is "-ad=1:4,1:5,1:6" or
"-ad=1:4:0,1:5:0,1:6:0".
If you change the controller mode from SCSI mode to RAID mode, data loss may occur. Back up any data you
require before changing the modes.
Open Issues and Resolutions
Fixed Issues/def
RAIDCFG Issues
You cannot delete a virtual disk on CERC SATA 2S when RAID 1 is created with the "--clear" option. The virtual disk
can be cleared from the controller BIOS.
You can assign up to 10 Global Hotspares using Raidcfg. Use The Dell OpenManage Server Administrator Storage
Management for assigning more than 10 Global Hot spares.