User's Manual

46 Preparing the Directory Structure for Deployment in Microsoft Windows PE
9
In the
unattend.txt
file, modify the following mandatory fields as in
Table 3-7.
10
Boot the target system with DTK Windows PE image.
11
After WinPE starts, make sure that the server is able to ping the
management station.
12
Run the following command to connect the target system to the shared
folder
os_deploy
.
X:\Dell\Toolkit\Tools net use z: \\<IP address of
the management station>\os_deploy
Table 3-7. Mandatory Fields in unattend.txt
Field Example
OEMBootFiles
For a R515 system that has H700 controller, you must retain
the following entries and remove the rest of the entries under
the field
OEMBootFiles.
percsas2.sys
oemsetup.inf
percsas2.cat
txtsetup.oem
NOTE: These are the files located in the
os_deploy\Dell\x32\toolkit\systems\PER515\$OEM$.NET\textmo
de folder.
MassStorageDri
vers
For a R515 system that has H700 controller, you must retain
the following entry and remove the rest of the entries under
the field
MassStorageDrivers.
"DELL PERC H700/H800 RAID Controller
Driver (Server 2003 32 bit)"="OEM"
NOTE: This driver description string must match the string
defined in the right-hand side of the SCSI section of the
Textsetup.oem file.