Quick Reference Guide

SYSCFG 61
--memoperatingmode optimizer,
mirror,
advancedecc
This option selects the memory
operating mode. This feature is
active only if a valid memory
configuration is detected.
Example:
A:>syscfg --
memoperatingmode=
optimizer
memoperatingmode=
optimizer
PowerEdge xx1x
systems
--memprefailurenotify enable, disable This option enables or disables
the Correctable ECC SMIs.
When enabled, the SMIs report
the Correctable ECC errors.
This option can be replicated.
Example:
A:>syscfg --
memprefailurenotify=
enable
memprefailurenotify=
enable
PowerEdge
R710, R610, and
T610 systems
with Intel Xeon
processor.
--memremap off, auto This option enables or disables
memory remapping.
A:>syscfg --memremap=
off
memintleave=off
All PowerEdge
systems
--memtest enable, disable This option enables or disables
the POST extended memory test.
Example:
A:>syscfg --memtest=
disable
memtest=disable
All PowerEdge
systems
Table 3-2. SYSCFG Options and Arguments for BIOS Configuration
(continued)
Option Valid
Arguments
Description Applicable
Systems