Quick Reference Guide

RAIDCFG 173
FILE LOCATION: C:\Work\DTK\DTK_CLI_3.4\Source\DTKCLc04.fm
DELL CONFIDENTIAL – PRELIMINARY 12/3/10 - FOR PROOF ONLY
-ad -c=id
or
adisk
controllerid=
id vdisk=id
-ad=
ch:targ,ch:t
arg,...
adisk=
channel:tar
get,
channel:tar
get,...
<valid
array disk>
<valid
array disk>
Displays information about the specified
array disk. This option combination is
mandatory.
Example:
A:>raidcfg -ad -c=2 -ad=
0:1,0:2
Controller: PERC 4e/DC
****** Physical Drive ******
Drive Vendor: SEAGATE
Drive Model: ST336607LC
Drive Location: 0:1:0
Drive Size: 34680 MB
Drive Avail: 0 MB
****** Physical Drive ******
Drive Vendor: FUJITSU
Drive Model: MAP3367NC
Drive Location: 0:2:0
Drive Size: 34680 MB
Drive Avail: 34680 MB
RAIDCFG Command successful!
Table 4-5. Enumerating Array Disks (Hard Drives)
(continued)
Mandatory
Options and
Arguments
Optional
Parameter
Valid
Parameter
Arguments
Description