Quick Reference Guide

66 SYSCFG
--qpibandwidthpriority compute, io This option sets the band width
priority to compute or io. Set to
compute for computation-
intensive applications. Set to io
for I/O-intensive applications.
This option can be replicated.
Example:
A:>syscfg --
qpibandwidthpriority=
compute
qpibandwidthpriority=
compute
Dell PowerEdge
xx1x systems
--redmem off, spare,
mirror, raid
This option allows selection of the
desired redundant memory mode,
or disables redundant memory.
This option can be replicated.
Example:
A:>syscfg --redmem=off
redmem=off
NOTE: The system must be
rebooted for BIOS options to take
effect.
All Dell
PowerEdge
systems except
xx1x
Table 3-2. SYSCFG Options and Arguments for BIOS Configuration
(continued)
Option Valid
Arguments
Description Applicable
Systems