Quick Reference Guide

Messages and Codes 231
218 Unable to determine optimum size for Virtual
disk. Ensure that the array disks are of the
same protocol (i.e. SAS, SATA, SCSI). If
there is a mismatch of the array disks then
the RAIDCFG will not be able to determine
the optimum size. In addition, also ensure
that there is drive size available for the
specified virtual disk.
219 One or more array disks selected to create
virtual disk or hotspare doesn't have enough
disk space. Please make sure that all the
array disks and failover drives selected
have enough free space.
220 The number of array disks provided is
incorrect for the requested RAID Type! RAID
1 requires exactly 2 array disks, RAID 5
requires at least 3 array disks, RAID 10
requires at least 4 array disks and RAID 50
requires at least 6 array disks.
221 Input file cannot be read.
222 Input file not found.
223 Error in opening the file.
Table A-5. RAIDCFG Error Codes and Messages
(continued)
Error Code Message