Quick Reference Guide
112 SYSCFG
serialcfgparams
or
scp
Configures and
displays serial
configuration
parameters. This
option can be
replicated.
All Dell
PowerEdge
systems
--
connectionmo
de
basic, terminal Sets the connection
mode used to
perform IPMI
messaging to the
BMC. This suboption
can be replicated.
--
msgcommflow
ctrl
noflowctrl,
rtscts
Sets the IPMI
message
communication flow
control. This
suboption can be
replicated.
--
msgcommdtrh
angup
NA Reports the IPMI
message
communication DTR
hang-up. This
suboption cannot be
replicated.
--
msgcommbitra
te
9600, 19200,
57600, 115200
Sets the IPMI
message
communication baud
rate in bits per
second (bps). This
suboption can be
replicated.
Table 3-5. BMC and Remote Access Controller Configuration Options
(continued)
Option Suboption Valid
Arguments
Description Applicable
Systems