Quick Reference Guide
SYSCFG 87
--filter fanfail, voltfail,
discretevoltfail,
tempwarn,
tempfail,
intrusion,
redundegraded,
redunlost,
procwarn, procfail,
powerwarn,
powerfail,
hardwarelogfail,
autorecovery,
batterywarn,
batteryfail,
powerabsent,
procabsent,
systempowerwarn,
systempowerfail
Specifies a PEF value.
This suboption can
be replicated.
See "BMC Platform
Events Filter Alert
Messages" for a
complete list of all
possible PEF messages
along a description of
each event.
NOTE: The fanfail
option is not supported
on x0xx systems.
--filteraction powercycle, reset,
powerdown,
powerreduction,
none
Sets the event filter
action for the filter
specified using the
filter suboption. This
suboption depends on
the filter suboption.
This suboption can
be replicated.
Table 3-5. BMC and Remote Access Controller Configuration Options (continued)
Option Suboption Valid Arguments Description