Quick Reference Guide

394 Summary of SYSCFG and RAIDCFG Options
-i <filename> Reads the RAID configuration
information from the given .ini
filename and creates the RAID
configurations on the specified
controllers.
Mandatory.
See
Table 4-11
for specific
usage
information.
-l
or
logfile
<filename> Logs command line output to a file. Optional.
See
Table 4-12
for specific
usage
information.
-o <filename> Reads the RAID configurations from
all available controllers and write
these configurations in the given .ini
filename.
Mandatory.
See
Table 4-11
for specific
usage
information.
-r
or
raid
<valid RAID level
number>
Sets the RAID level for the array.
Valid RAID values are 0, 1, 5, 10, 50.
If no value is specified for RAID, 0 is
taken as the default level.
Optional.
See Table 4-4
for specific
usage
information.
-rp
or
readpoli
cy
ra, ara, nra, rc, nrc Sets the read policy for the virtual
disk.
Optional.
See Table 4-4
for specific
usage
information.
Table E-2. RAIDCFG Short and Long Format Options (continued)
Option Valid Arguments Short Description Mandatory or
Optional