description of each event are listed in Table C-1.
Table C-1. BMC PEF Alert Events
Event Description
Fan Probe Failure The fan is running too slow or not at all.
Voltage Probe Failure The voltage is too low for proper operation.
Discrete Voltage Probe
Failure
The voltage is too low for proper operation.
Temperature Probe Warning The temperature is approaching excessively high or
low limits.
Temperature Probe Failure The temperature is either too high or too low for
proper operation.
Chassis Intrusion Detected The system chassis has been opened.
Redundancy (PS or Fan)
Degraded
Redundancy for the fans and/or power supplies has
been reduced.
Redundancy (PS or Fan)
Lost
No redundancy remains for the system's fans and/or
power supplies.
Processor Warning A processor is running at less than peak performance
or speed.
Processor Failure A processor has failed.
PPS/VRM/DCtoDC
Warning
The power supply, voltage regulator module, or
DC-to-DC converter is pending a failure condition.
Power Supply/VRM/D2D
Failure
The power supply, voltage regulator module, or
DC-to-DC converter has failed.
Hardware log is full or
emptied
Either an empty or a full hardware log requires
administrator attention.