Quick Reference Guide
DRAC III, DRAC 4, and DRAC 5 Property Database Group and Object Definitions 289
cfgRacTuneTi
mezoneOffset
Specifies the timezone
offset (in minutes) from
GMT/UTC to use for the
RAC Time. Some common
timezone offsets for
timezones in the United
States are shown below:
-480 (PST — Pacific
Standard Time)
-420 (MST — Mountain
Standard Time)
-360 (CST — Central
Standard Time)
-300 (EST — Eastern
Standard Time)
To modify this property,
you must have Configure
DRAC 5 permission. This
object has read/write
attributes.
-720 – 780 0
cfgRacTune
WebserverEn
able
Enables and disables the
RAC webserver. If this
property is disabled, the
RAC will not be accessible
using client web browsers
or remote RACADM. This
property has no effect on
the telnet/ssh/serial or local
RACADM interfaces.
To modify this property,
you must have Configure
DRAC 5 permission. This
object has read/write
attributes.
0 (FALSE)
1 (TRUE)
1
Table A-3. DRAC 5 Object Groups and Objects
Object Group Objects Description Valid Values Default