Quick Reference Guide

244 DRAC III, DRAC 4, and DRAC 5 Property Database Group and Object Definitions
cfgSerialCom2Re
dirEnable
Enables/disables the
console through the
COM 2 port.
To modify this property,
you must have Configure
DRAC 4 permission. This
object has read/write
attributes.
0=Disabled,
1=Enabled
1=COM 2
(console
enabled)
cfgSerialTelnet7fls
Backspace
When enabled, the
DRAC 4 will interpret
0x7f characters as
backspaces from a telnet
session. Some telnet
clients send 0x7f
characters when you press
<Backspace>. Normally,
when you press
<Backspace>, 0x08
characters are sent.
To modify this property,
you must have Configure
DRAC 4 permission. This
object has read/write
attributes.
0=Disabled,
1=Enabled
0
Table A-2. DRAC 4 Object Groups and Objects (continued)
Object Group Objects Description Valid Values Default