Quick Reference Guide
DRAC III, DRAC 4, and DRAC 5 Property Database Group and Object Definitions 243
cfgSerialConsole
Command
The serial command runs
after login at the start of a
session and allows you to
set up a command such
as connect com2 that
autoruns when a session
begins.
To modify this property,
you must have Configure
DRAC 4 permission.This
object has read/write
attributes.
connect com2 Empty string
(no
command)
cfgSerialHistory
Size
Sets the size of the serial
history buffer..
To modify this property,
you must have Configure
DRAC 4 permission.This
object has read/write
attributes.
Any integer
less than or
equal to 8192.
(If a value
larger than
8192 is
supplied, no
error is
returned and
the history size
is set to 8192.)
8192
characters
cfgSerialSshEnable
Enables/disables secure
shell on the DRAC 4.
To modify this property,
you must have Configure
DRAC 4 permission.This
object has read/write
attributes.
0=disabled,
1=enabled
1=enabled
cfgSerialTelnetEn
able
Enables/disables Telnet
console. To modify this
property, you must have
Configure DRAC 4
permission.This object
has read/write attributes.
0=disabled,
1=enabled
0=Telnet
disabled
Table A-2. DRAC 4 Object Groups and Objects (continued)
Object Group Objects Description Valid Values Default