Quick Reference Guide

SYSCFG 57
pefcfgparams
or
pcp
(continued)
Example (to set the PEF configuration
parameters):
Example 1 (To configure the PEF so that the system
is powered down in response to a fan failure event):
A:>syscfg pefcfgparams
--filter=fanfail
--filteraction=powerdown
pefcfgparams
filter=fanfail
filteraction=powerdown
Example 2 (To configure the PEF so that a
PEF alert is not sent to the destination IP address
in response to a chassis intrusion event):
A:>syscfg pefcfgparams
--filter=intrusion
--filteralert=disable
pefcfgparams
filter=intrusion
filteralert=disable
--powerbutton NA enable, disable This option enables or disables the power button.
This option can be replicated.
Example:
A:>syscfg --powerbutton=enable
powerbutton=enable
Table 3-3. BMC and Remote Access Controller Configuration Options (continued)
Options Suboptions Valid
Arguments
Description