Quick Reference Guide

Summary of SYSCFG and RAIDCFG Options 275
serialchannelinfo
or
sci
--mediumtype NA Displays serial channel information.
--prottype NA
--ssnsupport NA
--activessncount NA
serialcfgparams
or
scp
--connectionmode basic, terminal Configures and displays serial
configuration parameters.
NOTE: The BMC firmware does not
support serial port Point-to-Point
Protocol (PPP) configurations.
--
msgcommflowctrl
noflowctrl, rtscts
--
msgcommdtrhang
up
NA
--msgcommbitrate 9600, 19200
--tmcfglineediting enable, disable
--tmcfgdelctrl del, bksp
--tmcfgechoctrl echo, noecho
--
tmcfghandshakect
rl
enable, disable
--tmcfgnewlineseq noterm, crlf, null,
cr, lfcr, lf
--
tmcfginputnewlin
eseq
cr, null
serialuseraccess
or
sua
--usrprivlmt user, operator,
administrator,
noaccess
Configures and displays user access
parameters for the serial channel.
--userid 2–10
--
currentenableduse
rids
NA
--
useridswithfixedn
ames
NA
Table E-1. SYSCFG Options (continued)
Options Suboptions Valid Arguments Description Replicated