Quick Reference Guide

BMC Platform Events Filter Alert Messages 243
BMC Platform Events Filter Alert Messages
All possible Platform Event Filter (PEF) Alert Messages along with a description of each event are
listed in Table C-1.
Table C-1. BMC PEF Alert Events
Event Description
Fan Probe Failure The fan is running too slow or not at all.
Voltage Probe Failure The voltage is too low for proper operation.
Discrete Voltage Probe Failure The voltage is too low for proper operation.
Temperature Probe Warning The temperature is approaching excessively high or low limits.
Temperature Probe Failure The temperature is either too high or too low for proper operation.
Chassis Intrusion Detected The system chassis has been opened.
Redundancy (PS or Fan) Degraded Redundancy for the fans and/or power supplies has been reduced.
Redundancy (PS or Fan) Lost No redundancy remains for the system's fans and/or power supplies.
Processor Warning A processor is running at less than peak performance or speed.
Processor Failure A processor has failed.
PPS/VRM/DCtoDC Warning The power supply, voltage regulator module, or DC-to-DC converter is
pending a failure condition.
Power Supply/VRM/D2D Failure The power supply, voltage regulator module, or DC-to-DC converter
has failed.
Hardware log is full or emptied Either an empty or a full hardware log requires administrator attention.
Automatic System Recovery The system is hung or is not responding and is taking an action
configured by Automatic System Recovery.