DRAC III and DRAC 4 Property Database Group and Object Definitions 215
where <statMask> has the following bit definitions:
Bit-0: 1 = Send alert when system transitions to a powered-on state.
Bit-1: 1 = Send alert when system transitions to a powered-off state.
Bit-2: 1 = Send alert when watchdog timer detects a system hang.
Bit-3: Reserved.
Alert Filter Properties
The alert filter property group ID is cfgUserAdmin. The object IDs are shown in Table A-6.
Alert Test Commands
You can test alerts using test commands. The racadm command has subcommands that test the
different types of alert interfaces. These object ID sets cause the firmware to execute the subcommand with
the option that indicates the test alert type to test. The test message is preset in properties for each test
alert type. The types of alerts are email and trap.
The following subsection describes the command interfaces and the operation of the subcommand for
each option.
Table A-6. Alert Filter Property Group and Object IDs
GroupID Object ID Object Default Value
cfgUserAdmin cfgUserAdminPageEmailEnable FALSE
cfgUserAdmin cfgUserAdminPageEmailAddress ""
cfgUserAdmin cfgUserAdminPageEmailCustomMsg ""
cfgUserAdmin cfgUserAdminAlertFilterRacEventMask 0x777777
cfgUserAdmin cfgUserAdminAlertFilterSysEventMask 0x777777
cfgRemoteHosts cfgRhostsSmtpServerIpAddr 0.0.0.0
cfgOobSnmp cfgOobSnmpTrapsEnable TRUE
cfgTraps cfgTrapsDestIpAddr 0.0.0.0
cfgTraps cfgTrapsEnable FALSE
cfgTraps cfgTrapsSnmpCommunity ""
cfgTraps cfgTrapsFilterRacEventMask 0x777777
cfgTraps cfgTrapsFilterSysEventMask 0x777777