170 DRAC III and DRAC 4 Property Database Group and Object Definitions
cfgRacTuneDialOutIdleTime (Read/Write)
Valid Values
Integer from 0 to any positive value.
Default
0x28 or 40
Description
0=infinite, otherwise, when line is idle for this many seconds, the line is disconnected. This object
requires a RAC reset before it becomes active. (Enter hexadecimal values.)
cfgRacTuneDialOutMaxConnectTime (Read/Write)
Valid Values
Integer from 1 to 128.
Default
0x0
Description
0=infinite, otherwise, maximum time in seconds that the link will stay connected before the connection
is terminated.
This object requires a RAC reset before it becomes active. (Enter hexadecimal values.)
cfgRacTuneD3debugEnable (Read/Write)
Valid Values
Boolean, either 1 or 0 (TRUE or FALSE).
Default
1
Description
0=disable, 1=enable the RAC debug command.
This object requires a RAC reset before it becomes active.