150 DRAC III and DRAC 4 Property Database Group and Object Definitions
Description
A string of digits consisting of the following: 0-9, SENI. In the numeric message, S will be replaced by the
decimal value of the message severity. The E is replaced by the three-decimal digit event number.
The N is replaced by the two-decimal digit sensor number. The I is replaced by the IP address of the RAC
(dotted-decimal notation with the dots deleted).
NOTICE: It is possible to overflow the number of digits that a numeric pager can handle. Therefore, you must first
determine the maximum number of digits handled by the paging service and equipment in use.
cfgUserAdminPageNumericHangupDelay (Read/Write)
NOTE: This object property is for the DRAC III controller only.
Valid Values
Integer from 0 to any positive number.
Default
0x0
Description
Number of seconds to extend the time duration of a numeric page. (Enter hexadecimal values.)
cfgUserAdminPageAlphaEnable (Read/Write)
NOTE: This object property is for the DRAC III controller only.
Valid Values
Boolean either 1 or 0 (TRUE or FALSE).
Default
0
Description
0=disable, 1=enable alpha numeric paging on a per user basis.
cfgUserAdminPageAlphaNumber (Read/Write)
NOTE: This object property is for the DRAC III controller only.
Valid Values
A string of up to 95 ASCII characters.