Quick Reference Guide

138 DRAC III and DRAC 4 Property Database Group and Object Definitions
Description
0=disable, do not monitor the external power source.
1=always monitor the external power source.
2=only monitor the external power source if it is connected.
cfgMonitorBatteryRule (Read/Write)
Valid Values
0x1
Default
0x1
Description
The battery is not optional at the first release.
1=always monitor the onboard battery.
cfgLanNetworking
This group contains parameters to configure the RAC network adapter interface.
One instance of the group is allowed. All objects in this group require a RAC reset before they become
active. The following subsections describe the objects in this group.
cfgNicEnable (Read/Write)
Valid Values
Boolean, either 1 or 0 (TRUE or FALSE).
Default
1
Description
0=disable
1=enable the RAC network adapter.
NOTE: This object requires a RAC reset before it becomes active.