NOTE: Additionally, the "--redmem" option should not be issued
with any other command and should be immediately followed
by a system reboot. This note is important when you
develop scripts that can alter the "--redmem" setting.
- For options that use text strings such as username,
password, hostname, and community string, using characters
such as <space>, "<," ">," "|," "=" on the command line can be
misinterpreted by the command line parser and may cause errors.
Use only alphanumeric characters to avoid these errors.
- An option for Demand-based power management has been added.
Valid arguments are "enable" and "disable."
- A "--solaction" option has been added for PowerEdge x9xx
systems. This option enables or disables Serial-Over-LAN
(SOL) access for a particular user.
Suboptions Valid Arguments
-----------------------------------------------
--userid Userid(2-16)
--action enable,disable
- A "--memintleave" option has been added which can enable or
disable memory interleave mode. Valid arguments are
<enable,disable>.
- If you set the username using the syscfg "username" option,
SOL access for the corresponding user will be enabled by
default. You can disable SOL access for a user using the
"syscfg solaction --userid=<userid> --action=disable" command.
- Three additional filters have been added for PEFCFGPARAMS
(PCP) for PowerEdge x9xx series systems. These filters are
for battery warning ("batterywarn"), battery failure
("batteryfail"), and a filter for the presence of the
power supply in the system ("powerabsent").
* RAIDCFG:
- When creating virtual disks, the chunk (stripe) size is always
in KBs. Do not specify any units of measure for the chunk size.
- When providing multiple physical disks for the "create
virtual disk" command, do not separate the disks with spaces.
For example, "-ad=1:4, 1:5" causes an error. The correct way
to display multiple physical disks is "-ad=1:4,1:5,1:6."
- If you change the controller mode from SCSI mode to RAID mode,