Users Guide
The Dell PowerVault MD Storage Arrays are not classified
as "DELLMDARRAY" although the discovery agents and
the AOCs are correct
Ensure that you have performed the following steps:
1. Provide the PowerVault MD Storage Array controller IP.
2. Navigate to the $NCHOME/precision/dell/ folder and ensure that the following files and libraries are
available:
• dell_MD_Array_Common
• dell_OMC_ITNM_Client_v_3_0
• dell_OMC_ITNM_Helper_v_3_0
• SYMsdk
3. Check that the PowerVault MD Storage Array is reachable.
Polling for Dell Servers (Windows, Linux), Dell FX2 CMC,
VRTX CMC, CMC, and Dell DRACs does not occur
Ensure that you have performed the following steps:
1. Check that the devices are not in the un-managed state
2. Check that the required poll policies XML file has been imported using get_policies.pl.
3. Check that the required poll policies are enabled.
4. Check that the appropriate devices are discovered and classified for polling.
Polling for Dell servers running ESXi does not occur
Ensure that you have the performed the following steps:
1. Ensure that the Java path provided by ITNM IP Edition exists before the custom Java path in the
environmental variable PATH. If the path does not exist, configure the path as follows: %NCHOME%
\platform\<Arch>\jre_1.6.7\jre\bin
NOTE:
• On Systems running Windows: The <Arch> is win32.
• On systems running Linux: The <Arch> is linux2x86.
Configure the environmental variable DELL_OMC_ITNM_JAVA_PATH. This should contain the
complete IBM Java path (including the Java binary). Copy the environmental variable
DELL_OMC_ITNM_JAVA_PATH to /etc/profile file, to ensure that the environment variable is
available in all shells
For Example:
• On Systems running Windows:
%NCHOME%\platform\win32\jre_1.6.7\jre\bin\java.exe
• On systems running Linux:
$NCHHOME/platform/linux2x86/jre_1.6.7/jre/bin/java
52